סרוק את קוד WeChat כדי ליצור איתנו קשר

בואו ניצור קשר!

אתם מוזמנים לשלוח לנו מייל ואנו נענה לכם בהקדם האפשרי.

טופס יצירת קשר

הסבר על דרגת בריח רכבת: 8.8, 10.9, 12.9 & מעבר

When you buy railway fish bolts or other high-strength fasteners, לעתים קרובות תראה סימנים כגון 8.8, 10.9, אוֹ 12.9 על הציור, הַצָעַת מְחִיר, או תעודת בדיקה. במבט ראשון, the choice seems simple: a higher number means a stronger bolt. לְמַעֲשֶׂה, railway fastener selection is not quite that straightforward. These numbers are ISO property classes of railway bolt grade used to describe the mechanical properties of carbon steel and alloy steel bolts, ברגים, and studs. ISO 898-1:2013 defines the requirements for these property classes. The railway application, אוּלָם, may also be governed by UIC, IN, ASTM, ארמה, national standards, or a project-specific specification.

That distinction matters. A bolt can have the required strength on a material certificate and still be unsuitable for a particular rail joint if the dimensions, שִׁכבָה, preload, thread system, or applicable railway standard are wrong.

So how should you compare 8.8, 10.9 ו 12.9 railway bolts?

Railway bolts showing ISO property classes 8.8, 10.9 and 12.9 with 800, 1000 and 1200 MPa tensile strength
Comparison of railway bolt property classes 8.8, 10.9 ו 12.9, showing their nominal tensile strength levels and the importance of selecting the grade according to joint design, preload requirements and applicable railway standards.

What Do 8.8, 10.9 ו 12.9 Actually Mean?

The two numbers in a property class are not a product model number.

לְדוּגמָה, in the ISO property-class system:

  • 8.8 indicates a nominal minimum tensile strength of 800 MPa and a nominal yield-to-tensile ratio of 0.8.
  • 10.9 indicates a nominal minimum tensile strength of 1,000 MPa and a ratio of 0.9.
  • 12.9 indicates a nominal minimum tensile strength of 1,200 MPa and a ratio of 0.9.

This gives a useful first comparison:

Property ClassNominal Tensile StrengthNominal Yield Strength*
8.8800 MPa640 MPa
10.91,000 MPa900 MPa
12.91,200 MPa1,080 MPa

*The table is a simplified explanation of the property-class designation. Actual specified mechanical properties depend on the applicable standard, diameter range, and test requirements.

The important point is that 8.8, 10.9 ו 12.9 describe mechanical strength classes. They do not, by themselves, tell you whether a bolt is suitable for a fish plate, מערכת הידוק מסילה, bridge structure, or another railway connection.

That decision comes later.

Railway Bolt צִיוּן 8.8: A Common Choice for General Applications

Railway Bolt Grade 8.8 is widely used for general-purpose high-strength bolting. It offers a useful balance between strength, ductility, availability and manufacturing cost.

עבור יישומי רכבת, an 8.8 bolt may be considered for conventional fastening systems, רכיבי מסלול, structural connections and other applications where the project specification calls for this property class.

The advantage of 8.8 is not simply its 800 חוזק מתיחה MPa.

It is also relatively forgiving compared with higher-strength classes. Railway bolts are installed in environments that are not always ideal. Threads may become dirty. Components may have small dimensional variations. Maintenance work may take place outdoors, at night, or under tight possession windows.

That does not mean installation quality is unimportant. It means that the overall engineering balance of the fastener can be attractive for applications that do not require a higher strength class.

For a fish bolt, אוּלָם, the property class should never be selected only from the bolt diameter or from what another railway uses. The rail profile, fish plate design, required preload, joint arrangement and applicable standard all need to be considered.

Railway Bolt צִיוּן 10.9: When Higher Strength Is Required

Moving from 8.8 אֶל 10.9 gives a substantial increase in tensile and yield strength.

That can be useful where a connection needs higher preload or where the available bolt size is limited by the joint design.

ביישומי רכבת, higher-strength fasteners may be considered for heavily loaded joints, demanding structural connections and applications where the project specification requires a higher property class.

But there is an important point that is sometimes missed:

A stronger bolt does not automatically create a stronger joint.

The joint still depends on the quality of the threads, the contact surfaces, the nut and washer, the bolt preload, the alignment of the components and the design of the connection.

Imagine two bolts installed in the same joint. One is railway bolt Grade 10.9 but is installed with poor preload control. The other is railway bolt Grade 8.8 and is correctly installed according to the project specification.

The higher-strength bolt does not automatically win.

This is particularly important for railway track joints because repeated wheel loads create cyclic loading. The goal is not simply to prevent the bolt from breaking. The joint also needs to maintain the required clamping force during service.

Railway Bolt צִיוּן 12.9: Stronger, But Not Automatically Better

Railway Bolt Grade 12.9 is a higher-strength property class than 10.9, but that does not make it the universal choice for railway fasteners.

Higher-strength fasteners generally require more careful control of material condition, טיפול בחום, surface treatment and installation.

They also have less room for plastic deformation than lower-strength classes. In a connection with poor alignment, חוטים פגומים, incorrect preload or other stress concentrations, simply choosing a higher strength class does not solve the underlying problem.

This is why I would be cautious about specifications that say:

“Use Railway Bolt Grade 12.9 because it is safer.”

That is not really an engineering specification.

שאלה טובה יותר היא:

What load does the joint need to carry, what preload is required, and which property class does the applicable standard or engineering calculation specify?

צִיוּן 12.9 can make sense in special applications where the design requires it. But it should be selected because the connection requires that level of performance—not simply because 12.9 is the highest number on the shelf.

Why Torque Matters So Much

When discussing railway bolt grades, it is tempting to focus on tensile strength and ignore installation.

That is a mistake.

Bolt torque is used as a practical method of achieving the required preload, but torque is not a universal number for a particular railway bolt grade.

The relationship between torque and preload is affected by factors such as:

  • Bolt diameter and thread geometry
  • Thread condition
  • Nut and washer condition
  • Lubrication
  • Surface coating
  • חיכוך
  • Required joint preload

מסיבה זו, a generic statement such as “an M24 Grade 8.8 bolt should always be tightened to X Nm” can be misleading.

The correct torque or installation method should come from the relevant railway specification, fastener supplier’s technical data, or the joint design.

This is also why a calibrated torque tool matters. If installation teams use different tools, lubricants or tightening procedures without accounting for friction changes, the same torque reading may not produce the same preload.

For railway fish bolts, maintaining preload is often more important than simply choosing the strongest available bolt.

If you are dealing with recurring joint loosening, it is worth investigating the installation process before automatically changing from 8.8 אֶל 10.9 אוֹ 12.9.

You may find that the problem is actually related to preload, joint movement, component wear, thread condition or installation procedure.

Railway fish bolt joint assembly showing rail joint, fish plate, bolt, nut and preload force
A railway fish bolt joint connects two rail sections using fish plates and high-strength bolts. The joint performance depends on the combined effect of bolt grade, preload control, and joint design.

Coating and Hydrogen Embrittlement

Surface treatment becomes increasingly important as fastener strength increases.

High-strength steel fasteners can be susceptible to hydrogen embrittlement under certain processing and service conditions. Hydrogen can be introduced during some cleaning, pickling, plating or coating processes. If the steel, processing route and stress condition are unfavorable, delayed brittle failure can occur.

This is one reason why coating should not be treated as a cosmetic choice.

For Railway Bolt Grade 10.9 and especially railway bolt Grade 12.9 מחברים, the coating system should be selected together with the fastener material and the applicable standard. The supplier should be able to explain the surface-treatment process and the controls used to manage hydrogen-embrittlement risk where applicable.

The correct solution may vary depending on the coating system and project requirements.

For railway applications exposed to rain, לַחוּת, coastal air, tunnels or de-icing environments, corrosion protection also needs to be considered. A bolt that has excellent mechanical properties but loses its section through corrosion is not a reliable fastener.

Do the Nut and Washer Need to Match the Bolt?

כֵּן.

A high-strength bolt should not be evaluated by itself.

The nut, washer, threads and mating components form a joint. If one component has inadequate strength or the wrong geometry, upgrading the bolt alone may provide little benefit.

לְדוּגמָה, using a railway bolt Grade 10.9 bolt with an unsuitable nut does not create a Grade 10.9 connection.

The same principle applies to washers and anti-loosening arrangements. A spring washer, locking nut or other device should not be selected simply because it was used on another railway project.

The connection should be designed around the actual vibration, load and maintenance conditions.

Railway Standards Matter More Than the Number on the Bolt

This is where railway fasteners differ from a simple hardware-store comparison.

A drawing may specify a bolt property class such as 8.8 אוֹ 10.9, but it may also specify:

  • Bolt dimensions
  • Thread standard
  • Head dimensions
  • Nut requirements
  • Washer requirements
  • חוֹמֶר
  • טיפול בחום
  • שִׁכבָה
  • בְּדִיקָה
  • Marking
  • בדיקה מכנית
  • תקן רכבת ישים

במילים אחרות, 8.8 is not a complete bolt specification.

The same applies to 10.9 ו 12.9.

North American projects may use ASTM specifications for structural fasteners, while other railway systems may reference EN, UIC, national or project-specific requirements. ASTM F3125/F3125M, לְדוּגמָה, consolidates several previous structural-bolt specifications including A325 and A490. It should not be treated as a simple one-to-one conversion table with ISO 898 property classes.

If your drawing says ASTM, follow the ASTM requirement. If it specifies ISO 898-1 property class 10.9, follow that requirement. If the railway project specifies a particular UIC, EN or national standard, that standard takes priority.

Do not select a substitute just because the tensile strength appears similar.

How Should You Choose a Railway Bolt Grade?

There is no single railway bolt grade that is correct for every railway application.

A practical selection process looks more like this:

Questionלמה זה חשוב
What is the joint carrying?Determines the required load capacity
What preload is required?Influences bolt size and property class
Which railway standard applies?Defines the technical requirements
What are the environmental conditions?Affects corrosion and coating selection
How will the bolt be installed?Influences achievable preload
What nut and washer are required?The complete joint must work together
What inspection is required?Confirms production and installation quality

לְדוּגמָה, a conventional track connection may use Grade 8.8 if that is what the applicable design and standard require.

A more heavily loaded connection may require Grade 10.9.

A special application may require Grade 12.9.

The important part is the engineering process behind the decision.

A Simple Comparison

Property ClassStrength LevelTypical Consideration
8.8General high-strength classGood balance of strength, ductility and availability
10.9Higher-strength classUseful where higher preload or strength is required
12.9Very high-strength classSpecial applications requiring careful engineering and process control

This is a starting point, not a universal railway specification.

The final selection should always be checked against the actual joint design and applicable standard.

What Should a Railway Bolt Supplier Provide?

When buying railway fish bolts or other railway fasteners, I would not stop at asking:

“What railway bolt grade is it?”

Ask for the complete specification.

A reliable supplier should be able to provide information such as:

  • Material grade and property class
  • Applicable standard
  • Bolt dimensions and thread specification
  • Heat-treatment requirements
  • Mechanical test results
  • Hardness requirements where applicable
  • Coating and surface-treatment details
  • Inspection records
  • Traceability information
  • Marking requirements
  • Packaging and identification

For larger railway projects, traceability is particularly important. The bolts delivered to the site should be linked back to the relevant production batch and inspection records.

That makes it much easier to investigate a problem if a joint later shows abnormal loosening, corrosion or damage.

rail fish plate and fish bolts connecting two rail sections
צלחות דגים מחברות את קצוות המסילה ושומרות על יישור בחיבורי המסילה.

השורה התחתונה: Higher Strength Is Not the Whole Story

The numbers 8.8, 10.9 ו 12.9 are useful because they give engineers a common way to describe bolt mechanical properties.

But a railway bolt is more than a strength number.

A reliable rail joint depends on the complete system: בְּרִיחַ, nut, washer, threads, mating components, preload, שִׁכבָה, installation and maintenance.

That is why I would not recommend choosing 12.9 simply because it is stronger than 10.9, or choosing 10.9 simply because another railway uses it.

Start with the joint.

Then check the applicable standard.

Then determine the required property class.

לְבָסוֹף, make sure the manufacturing and installation processes can consistently achieve the required performance.

בְּ Luoyang Fonyo Heavy Industries Co., בע"מ., we manufacture railway fasteners including בריח דג, צלחת דגים, תפסי מסילה אלסטיים ו רפידות מסילה, לפי ציורי הלקוח, applicable standards and project requirements. For railway fasteners, we can review the required material grade, מידות, טיפול בחום, coating and inspection requirements before production.

If you have a drawing, specification or existing bolt sample, send us the details. Our engineering team can help check the required railway bolt grade, applicable standard and production requirements before quotation.

שאלות נפוצות

What do 8.8, 10.9 ו 12.9 mean on a bolt?

They are ISO property classes used to describe the mechanical properties of carbon steel and alloy steel fasteners. במילים פשוטות, 8.8 corresponds to a nominal 800 חוזק מתיחה MPa, 10.9 אֶל 1,000 MPa, ו 12.9 אֶל 1,200 MPa.

The complete requirements depend on the applicable edition of the standard and the bolt diameter range.

Which railway bolt grade is best?

There is no single “best” grade.

צִיוּן 8.8 may be suitable where the design calls for a general high-strength fastener. צִיוּן 10.9 may be selected where greater strength or preload is required. צִיוּן 12.9 is generally reserved for applications where the engineering specification requires its higher strength level.

The applicable railway standard and joint design should determine the final choice.

Is a higher railway bolt grade always better?

לֹא.

A higher property class provides greater strength, but it does not automatically improve the performance of the complete joint. הַתקָנָה, preload, שִׁכבָה, קורוזיה, thread condition and component compatibility are also important.

Can I replace a Grade 8.8 bolt with a Grade 10.9 אוֹ 12.9 בְּרִיחַ?

Not automatically.

Changing the property class can affect preload, tightening requirements, טיפול פני השטח, nut selection and joint behavior. Any substitution should be approved against the applicable engineering specification.

What is the difference between ISO 8.8 and ASTM A325?

They belong to different specification systems and should not be treated as direct equivalents.

ASTM A325 and A490 were incorporated into the ASTM F3125/F3125M structural bolt specification system. The relevant ASTM specification should be followed when a project calls for ASTM fasteners.

How do I know which bolt grade to specify for fish plates?

Start with the rail and fish plate system, applicable railway standard, bolt dimensions, required joint preload and service conditions.

Do not choose the grade based only on axle load or bolt diameter. The complete joint needs to be considered.

Why do railway fish bolts loosen?

Loosening can result from insufficient or inconsistent preload, joint movement, רֶטֶט, worn components, incorrect tightening procedures, thread or contact-surface conditions, and other factors.

Changing to a higher-strength bolt may not solve the problem if the underlying joint condition has not been addressed.

עדכוני ניוזלטר

הכנס את כתובת הדוא"ל שלך למטה והירשם לניוזלטר שלנו